CAPS  DIN2617

CAPS

DIN 2617

Table  18   

                     
Outstde Diameter D1 Wall Thickness S Length   L
1 2 3
21.3 2 2.9   32
26.9 2.3 2.9   32
33.7 2.6 3.6    38
42.4 2.6 3.6   38
48.3 2.6 3.6   38
60.3 2.9 4 5.6 38
76.1 2.9 5.6 7.1 38
88.9 3.2 5.6 8 50
114.3 3.6 6.3 8.8 64
139.7 4 7.1 10 76
168.3 4.5 7.1 11 90
219.1 5.9 8 12.5 100
273 6.3 10 12.5 127

    Hote For Bevel detail see Table. 19 (DIN  2559)

DIN 2559

Edge Preparation for Welding

Table  19

Identi fication number Wall thickness a Denomination D Symbol Edge froms Section Dirnensions Weding processes
α β Gap b Gap depth c Flank depth h Root layer other layers
1 up to 3 Square butt weld p1 - - 0 to 3 - - SG.G -
21 up to 16 Single.V utt weld p2 40 to 60 for SG 60 for EandG - 0 to 3 - - E.SG.G E.SG.G to     s=10
22 up to 16 Single.V butt weld p3 40 to 60 for SG 60 for EandG - 0 to 4 up to 2 -
3 above 12 Single.U butt weld p4 - 8 0 to 3 up to 2 - E.SG
4 above 12 single.U butt weld   on          bevelled    gap p5 60 8 0 to 3 - 「4

1) For additional symbols. see DIN 1912.      

 2) The dimensions specifed apply to the tacked condition.                                                                                                                                              

 3) In the caye of austentic steel only with the puchaser's agreement.

 

                                                     Close

 Tel :  86-411-82633377   Fax : 86-411-82826969  
  Skype:aijikavalves
 E-mail :  Valves@aijika.com